Radiology · 510(k) · 2014

CVI42

CIRCLE CARDIOVASCULAR IMAGING INC. Cleared by FDA on 22 August 2014 under submission K141480, product code LLZ (system, image processing, radiological). What FDA's record says, in FDA's words.

Device record · K141480

  1. Device. CVI42DEVICE
  2. Company. CIRCLE CARDIOVASCULAR IMAGING INC (CA)COMPANY
  3. Decision. 22 August 2014, 510(k), substantially equivalent (traditional review); received 4 June 2014DECISION
  4. Panel. RadiologyPANEL
  5. Product code. LLZ, System, Image Processing, RadiologicalCODE
  6. Regulation. 21 CFR 892.2050, Class IIREG
  7. Source. FDA database entry · decision document (8 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

Cvi42 vascular analysis add-on is an image analysis software package add-on for evaluating CT and MR images of blood vessels. Combining digital image processing and visualization tools such as multiplaner reconstruction (MPR), thin/think maximum intensity projection (MIP) thin and think, inverted MIP thin and think, volume rendering technique (VRT), curved planner reformation, processing tools such as bone removal (based on both single energy and dual energy) table removal and evaluation tools (vessel centerline calculation, lumen calculation, stenosis calculation) and reporting tools (lesion location, lesion characteristics) and key images), the software package is designed to support the physician in conforming the presence or absence of physician identified lesion in blood vessels and evaluation, documentation and follow up of any such lesions. It shall be used by qualified medical professionals, experienced in examining and evaluating cardiovascular CT or MR images, for the purpose of obtaining diagnostic information as part of a comprehensive diagnostic decision-making process. cvi42 is a software application that can be used as a stand-alone product or in a networked environment. The target population for the cvi42 is not restricted.

K141480, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 19,970 reports filed against devices carrying product code LLZ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101631

Philips received a complaint on the IntelliSpace Cardiovascular (ISCV) indicating that the ISCV could only be accessed in Web-Only mode on the workstation. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint ((b)(4)).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101632

Philips received a complaint on the IntelliSearch Cardiovascular (ISCV) indicating that customer reported that study retrieval from the archive was either failing or taking an excessively long time to complete. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint (b)(4).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101634

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on […]

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101635

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user could not save the findings. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this […]

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101636

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user reported that it was not possible to view previous studies in Echo Module. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it […]

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code LLZ, in Radiology, from CIRCLE CARDIOVASCULAR IMAGING INC, or cleared in 2014. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.