Radiology · 510(k) · 2024
ProFound Detection (V4.0)
iCAD, Inc.. Cleared by FDA on 8 November 2024 under submission K240417, product code QDQ (radiological computer assisted detection/diagnosis software for lesions suspicious for cancer). What FDA's record says, in FDA's words.
Device record · K240417
- Device. ProFound Detection (V4.0)DEVICE
- Company. iCAD, Inc.COMPANY
- Decision. 8 November 2024, 510(k), substantially equivalent (traditional review); received 13 February 2024DECISION
- Panel. RadiologyPANEL
- Product code. QDQ, Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For CancerCODE
- Regulation. 21 CFR 892.2090, Class IIREG
- Source. FDA database entry · decision document (10 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
ProFound Detection V4.0 is a computer-assisted detection and diagnosis (CAD) software device intended to be used concurrently by interpreting physicians while reading digital breast tomosynthesis (DBT) exams from compatible DBT systems. The system detects soft tissue densities (masses, architectural distortions and asymmetries) and calcifications in the 3D DBT slices. The detections and Certainty of Finding and Case Scores assist interpreting physicians in identifying soft tissue densities and calcifications that may be confirmed or dismissed by the interpreting Physician.
The product code's definition, from FDA's classification record. A radiological computer assisted detection and diagnostic software for suspected lesions is an image processing device intended to aid in the detection, localization, and characterization of lesions suspicious for cancer on acquired medical images (e.g., mammography , MR, CT, ultrasound, radiography). The device detects, identifies and characterizes lesions suspicious for cancer based on features or information extracted from the images, and may provide information about the presence, location, and characteristics of the lesion to the user. Primary diagnostic and patient management decisions are made by the clinical user.
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Mentionsdetection or identification of findings
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 0 reports filed against devices carrying product code QDQ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code QDQ, in Radiology, from iCAD, Inc., or cleared in 2024. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.