Radiology · 510(k) · 2025
SpotLight / SpotLight Duo with Low Dose Lung Cancer Screening Option
Arineta Ltd.. Cleared by FDA on 15 April 2025 under submission K250650, product code JAK (system, x-ray, tomography, computed). What FDA's record says, in FDA's words.
Device record · K250650
- Device. SpotLight / SpotLight Duo with Low Dose Lung Cancer Screening OptionDEVICE
- Company. Arineta Ltd. (IL)COMPANY
- Decision. 15 April 2025, 510(k), substantially equivalent (traditional review); received 4 March 2025DECISION
- Panel. RadiologyPANEL
- Product code. JAK, System, X-Ray, Tomography, ComputedCODE
- Regulation. 21 CFR 892.1750, Class IIREG
- Source. FDA database entry · decision document (13 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
The SpotLight / SpotLight Duo is intended to produce cross-sectional images of the body by computer reconstruction of X-ray transmission projection data taken at different angles. The system has the capability to image cardiovascular and thoracic anatomies, including the heart, in a single rotation. The system may acquire data using Axial, Cine and Cardiac scan techniques from patients of all ages (DLIR is limited for patient use above the age of 2 years). These images may be obtained either with or without contrast. This device may include signal analysis and display equipment, patient and equipment supports, components and accessories. This device may include data and image processing to produce images in a variety of trans-axial and reformatted planes. The system is indicated for x-ray Computed Tomography imaging of cardiovascular and thoracic anatomies that fit in the scan field-of-view. The Low Dose CT Lung Cancer Screening Option for SpotLight / SpotLight Duo is indicated for using low dose CT for lung cancer screening. The screening must be conducted with the established program criteria and protocols that have been approved and published by a governmental body or a professional medical society. Information from professional societies related to lung cancer screening can be found but is not limited to: American College of Radiology (ACR) – resources and technical specification; accreditation American Association of Physicists in Medicine (AAPM) – Lung Cancer […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedCT, radiographs (X-ray)
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 5,281 reports filed against devices carrying product code JAK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
25 September 2026 · Malfunction · REVOLUTION EVO · GE MEDICAL SYSTEMS, LLC · report 50896044
The GE CT table wouldn't move during stroke. Patient had to be physically moved to resume scan, delay in care. GE CT table has had the same issues with the table working intermittently x 3 weeks. Multiple techs have worked on it and the same problem persists.
25 September 2026 · Malfunction · Needle Guide · Quantum Surgical SAS · report 3023140882-2026-00002
23 September 2026 · Malfunction · ILLUMISITE · COVIDIEN LP - SUPERDIMENSION INC · report 3004962788-2026-00087
It was reported that during the procedure, one locatable guide indicated as outside of the sensor sensing volume and another locatable guide had difficulty retracting from the extended working channel. The physician completed the superDimension portion of the case. No patient complications have been reported as a result of this event.
23 September 2026 · Other · NL4000 · Samsung HME America, Inc. · report 3004938766-2026-00043
23 September 2026 · Malfunction · ILLUMISITE · COVIDIEN LP - SUPERDIMENSION INC · report 3004962788-2026-00088
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code JAK, in Radiology, from Arineta Ltd., or cleared in 2025. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.