Radiology · 510(k) · 2024
uAI Easy Triage ICH
Shanghai United Imaging Intelligence Co., Ltd.. Cleared by FDA on 24 September 2024 under submission K242292, product code QAS (radiological computer-assisted triage and notification software). What FDA's record says, in FDA's words.
Device record · K242292
- Device. uAI Easy Triage ICHDEVICE
- Company. Shanghai United Imaging Intelligence Co., Ltd. (CN)COMPANY
- Decision. 24 September 2024, 510(k), substantially equivalent (traditional review); received 2 August 2024DECISION
- Panel. RadiologyPANEL
- Product code. QAS, Radiological Computer-Assisted Triage And Notification SoftwareCODE
- Regulation. 21 CFR 892.2080, Class IIREG
- Source. FDA database entry · decision document (16 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
uAI Easy Triage ICH is a radiological computer-assisted triage and notification software device indicated for analysis of non-enhanced head CT images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and prioritizing studies with suspected positive findings of lntracranial Hemorrhage (ICH).
The product code's definition, from FDA's classification record. Radiological computer-assisted triage and notification software is an image processing device intended to aid in prioritization and triage of time sensitive patient detection and diagnosis based on the analysis of medical images acquired from radiological signal acquisition systems. The device identifies or prioritizes time sensitive imaging for review by prespecified clinical users based on software-based image analysis but does not provide information from the image analysis other than triage and notification .
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedCT
- Mentionstriage or notification
- Mentionsdetection or identification of findings
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 0 reports filed against devices carrying product code QAS. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code QAS, in Radiology, from Shanghai United Imaging Intelligence Co., Ltd., or cleared in 2024. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.