Radiology · 510(k) · 2021

VBrain

Vysioneer Inc.. Cleared by FDA on 19 March 2021 under submission K203235, product code QKB (radiological image processing software for radiation therapy). What FDA's record says, in FDA's words.

Device record · K203235

  1. Device. VBrainDEVICE
  2. Company. Vysioneer Inc.COMPANY
  3. Decision. 19 March 2021, 510(k), substantially equivalent (traditional review); received 3 November 2020DECISION
  4. Panel. RadiologyPANEL
  5. Product code. QKB, Radiological Image Processing Software For Radiation TherapyCODE
  6. Regulation. 21 CFR 892.2050, Class IIREG
  7. Source. FDA database entry · decision document (12 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

VBrain is a software device intended to assist trained medical professionals, during their clinical workflows of radiation therapy treatment planning, by providing initial object contours of known (diagnosed) brain tumors (i.e., the region of interest, ROI) on axial T1 contrast-enhanced brain MRI images. Section 5. K203235 Vysioneer Inc. Traditional 510(k) Premarket Submission VBrain Section 5. VBrain uses an artificial intelligence algorithm (i.e., deep learning neural networks) to contour (segment) brain tumor on MRI images for trained medical professionals’ attention, which is meant for informational purposes only and not intended for replacing their current standard practice of manual contouring process. VBrain does not alter the original MRI image, nor does it intend to be used to detect tumors for diagnosis. VBrain is intended only for generating Gross Tumor Volume (GTV) contours of brain metastases, meningiomas, and acoustic neuromas on axial T1 contrast-enhanced MRI images; It is not intended to be used with images of other brain tumors. The user must know the tumor type when they use VBrain. VBrain is intended to be used on adult patients only. Medical professionals must finalize (confirm or modify) the contours generated by VBrain, as necessary, using an external platform available at the facility that supports DICOM-RT viewing/editing functions, such as image visualization software and treatment planning system.

K203235, FDA decision document · source

The product code's definition, from FDA's classification record. To provide semi-automatic or fully-automated radiological image processing and analysis tools for radiation therapy. Software implementing artificial intelligence (AI) including nonadaptive machine learning algorithms trained with clinical and/or artificial radiological images. In these devices, the algorithm training images typically impact device performance. AI based radiological image processing software is intended to be used in the workflow of radiation therapy. Adaptive AI algorithms are not within the scope of this product code. Primary radiation dose calculation or plan optimization for treatment planning are not within scope of this product code.

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 0 reports filed against devices carrying product code QKB. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code QKB, in Radiology, from Vysioneer Inc., or cleared in 2021. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files